RVA2-20-65
- Gas: Natural or propane
- BTU/h high fire: 65,000
- BTU/h low fire: 50,000
- Length: 21’-7”
- Weight: 120 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 6’ to 9'
- Not recommended for use in dairy or poultry applications.

RVA2-20-75
- Gas: Natural or propane
- BTU/h high fire: 75,000
- BTU/h low fire: 50,000
- Length: 21’-7”
- Weight: 120 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4”x10' aluminized steel
- *Mounting heights: 7’ to 10'

RVA2-20-80
- Gas: Natural or propane
- BTU/h high fire: 80,000
- BTU/h low fire: 52,000
- Length: 21’-7”
- Weight: 120 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 10'

RVA2-30-65
- Gas: Natural or propane
- BTU/h high fire: 65,000
- BTU/h low fire: 50,000
- Length: 31’-3”
- Weight: 160 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 6’ to 9'
- Not recommended for use in dairy or poultry applications.

RVA2-30-75
- Gas: Natural or propane
- BTU/h high fire: 75,000
- BTU/h low fire: 50,000
- Length: 31’-3”
- Weight: 160 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 10'

RVA2-30-80
- Gas: Natural or propane
- BTU/h high fire: 80,000
- BTU/h low fire: 52,000
- Length: 31’-3”
- Weight: 160 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 10'

RVA2-30-100
- Gas: Natural or propane
- BTU/h high fire: 100,000
- BTU/h low fire: 65,000
- Length: 31’-3”
- Weight: 160 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 8’ to 14'

RVA2-40-65
- Gas: Natural or propane
- BTU/h high fire: 65,000
- BTU/h low fire: 50,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 6’ to 9'
- Not recommended for use in dairy or poultry applications.

RVA2-40-75
- Gas: Natural or propane
- BTU/h high fire: 75,000
- BTU/h low fire: 50,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 12'

RVA2-40-80
- Gas: Natural or propane
- BTU/h high fire: 80,000
- BTU/h low fire: 52,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 12'

RVA2-40-100
- Gas: Natural or propane
- BTU/h high fire: 100,000
- BTU/h low fire: 65,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 7’ to 13'

RVA2-40-125
- Gas: Natural or propane
- BTU/h high fire: 125,000
- BTU/h low fire: 82,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 9’ to 13'

RVA2-40-150
- Gas: Natural or propane
- BTU/h high fire: 150,000
- BTU/h low fire: 100,000
- Length: 40’-11”
- Weight: 190 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 10’ to 14'
- Not recommended in
swine applications.

RVA2-50-100
- Gas: Natural or propane
- BTU/h high fire: 100,000
- BTU/h low fire: 65,000
- Length: 50’-7”
- Weight: 235 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 8’ to 12'

RVA2-50-125
- Gas: Natural or propane
- BTU/h high fire: 125,000
- BTU/h low fire: 82,000
- Length: 50’-7”
- Weight: 235 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 9’ to 14'

RVA2-50-150
- Gas: Natural or propane
- BTU/h high fire: 150,000
- BTU/h low fire: 100,000
- Length: 50’-7”
- Weight: 235 lbs
- Combustion chamber: Stainless steel
- Radiant tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 10’ to 14'
- Not recommended in
swine applications.
Recommended mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data.
Clearance to combustibles

RVA2 (20, 30, 40)-65, 75
Mount angle |
Sides | Top | Below |
0º |
9" | 6" | 60" |
45º | Front 39" Back 8" | 10" | 60"
|
0º | Front 29"
Back 8" | 6"
| 60"
|
0º | 9" | 6"
| 60"
|
0º | 7" | 6"
| 30"
|

RVA2 (20, 30, 40, 50)-80, 100
Mount angle |
Sides | Top | Below |
0º |
14" | 6" | 66" |
45º | Front 39" Back 8" | 10" | 66"
|
0º | Front 29"
Back 8" | 6"
| 66"
|
0º | 16" | 6"
| 66"
|
0º | 7" | 6"
| 30"
|

RVA2 (40, 50)-125
Mount angle |
Sides | Top | Below |
0º |
20" | 6" | 76" |
45º | Front 58" Back 8" | 10" | 76"
|
0º | Front 42"
Back 8" | 6"
| 76"
|
0º | 20" | 6"
| 76"
|
0º | 7" | 6"
| 30"
|

RVA2 (40, 50)-150
Mount angle |
Sides | Top | Below |
0º |
24" | 6" | 81" |
45º | Front 58" Back 8" | 10" | 81"
|
0º | Front 42"
Back 8" | 6"
| 81"
|
0º | 23" | 6"
| 81"
|
0º | 11" | 6"
| 44"
|
Clearances published in RVA2 Series manual and on warning label supersede data shown on this page. Reference RVA2 Series installation manual for complete information.
Heaters mounted on an angle between 0º and 45º must maintain clearances posted for 0º or 45º; whichever is greater.
Maintain a 10 in. (0° mounting angle) or 12 in. (1-45° mounting angle) clearance from ceilings constructed of tri-ply plastic or plastic fogger lines.