LS3-10-25

  • Gas: Natural or propane  
  • BTU/h input: 25,000 
  • Length: 12'-1"  
  • Weight: 70
  • *Mounting heights: 8'-11'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-10-30

  • Gas: Natural or propane  
  • BTU/h input: 30,000 
  • Length: 12'-1"  
  • Weight: 70
  • *Mounting heights: 8'-11'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-15-25

  • Gas: Natural or propane  
  • BTU/h input: 25,000 
  • Length: 16'-10"  
  • Weight: 85
  • *Mounting heights: 8'-13'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-15-30

  • Gas: Natural or propane  
  • BTU/h input: 30,000 
  • Length: 16'-10"  
  • Weight: 85
  • *Mounting heights: 8'-13'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-15-40

  • Gas: Natural or propane  
  • BTU/h input: 40,000 
  • Length: 16'-10"  
  • Weight: 85
  • *Mounting heights: 8'-13'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-20-40

  • Gas: Natural or propane  
  • BTU/h input: 40,000 
  • Length: 21'-10"  
  • Weight: 100
  • *Mounting heights: 8'-13'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

LS3-30-50

  • Gas: Natural or propane  
  • BTU/h input: 50,000 
  • Length: 31'-7"  
  • Weight: 120
  • *Mounting heights: 9'-14'
  • Combustion chamber: titanium treated steel  
  • Radiant emitter tubes: 16 ga. 3" aluminized steel

 * Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles.  

Clearance to combustibles

LS3 (10, 15)-25, 30


Mount
angle
Sides TopBelow

8"4"36"
45°
Front 39"
Back 8"
10"36"

1 side
shield
Front 29"
Back 8"
4"36"

2 side
shields
9" 4"36"

LS3 (15, 20)-40


Mount
angle
Sides TopBelow

15"6"45"
45°
Front 58"
Back 8"
10"45"

1 side
shield
Front 42"
Back 8"
6"45"

2 side
shields
20" 6"45"

LS3 (15, 20, 30)-50


Mount
angle
Sides TopBelow

11"6"48"
45°
Front 39"
Back 8"
10"48"

1 side
shield
Front 29"
Back 8"
6"48"

2 side
shields
16"" 6"48"

20 ft from
burner
7"6"30"

Clearances published in Ls3 Series manual and on warning label supersede data shown on this page. Reference LS3 Series installation manual for complete information.
Heaters mounted on an angle between 0º and 45º must maintain clearances posted for 0º or 45º, whichever is greater.