HLV-40
- Gas: Natural or propane
- BTU/h high fire: 40,000
- BTU/h low fire: no reduction for low fire
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 9’ to 14'
HLV-50
- Gas: Natural or propane
- BTU/h high fire: 50,000
- BTU/h low fire: no reduction for low fire
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 9’ to 14'
HLV-60
- Gas: Natural or propane
- BTU/h high fire: 60,000
- BTU/h low fire: 50,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 10’ to 15'
HLV-75
- Gas: Natural or propane
- BTU/h high fire: 75,000
- BTU/h low fire: 60,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 11’ to 18'
HLV-80
- Gas: Natural or propane
- BTU/h high fire: 80,000
- BTU/h low fire: 64,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 11’ to 18'
HLV-90
- Gas: Natural or propane
- BTU/h high fire: 90,000
- BTU/h low fire: 72,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 12’ to 20'
HLV-100
- Gas: Natural or propane
- BTU/h high fire: 100,000
- BTU/h low fire: 80,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 12’ to 20'
HLV-110
- Gas: Natural or propane
- BTU/h high fire: 110,000
- BTU/h low fire: 88,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 13’ to 23'
HLV-120
- Gas: Natural or propane
- BTU/h high fire: 120,000
- BTU/h low fire: 96,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 13’ to 23'
HLV-125
- Gas: Natural or propane
- BTU/h high fire: 125,000
- BTU/h low fire: 100,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 14’ to 27'
HLV-140
- Gas: Natural or propane
- BTU/h high fire: 140,000
- BTU/h low fire: 112,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 15’ to 30'
HLV-150
- Gas: Natural or propane
- BTU/h high fire: 150,000
- BTU/h low fire: 120,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 15’ to 30'
HLV-170
- Gas: Natural or propane
- BTU/h high fire: 170,000
- BTU/h low fire: 136,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 16’ to 40'
HLV-175
- Gas: Natural or propane
- BTU/h high fire: 175,000
- BTU/h low fire: 140,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 17’ to 42'
HLV-180
- Gas: Natural or propane
- BTU/h high fire: 180,000
- BTU/h low fire: 144,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 18’ to 47'
HLV-200
- Gas: Natural or propane
- BTU/h high fire: 200,000
- BTU/h low fire: 160,000
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” aluminized steel
- *Mounting heights: 19’ to 50'