DX3L-20-50


  • Gas: Natural or propane
  • BTU/h input: 50,000
  • Length: 21'-9"
  • Weight: 120
  • *Mounting heights: 9'-14'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-20-50


  • Gas: Natural or propane
  • BTU/h input: 50,000
  • Length: 21'-9"
  • Weight: 120
  • *Mounting heights: 9'-14'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-20-50


  • Gas: Natural or propane
  • BTU/h input: 50,000
  • Length: 21'-9"
  • Weight: 120
  • *Mounting heights: 9'-14'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-30-50


  • Gas: Natural or propane
  • BTU/h input: 50,000
  • Length: 31'-5"
  • Weight: 120
  • *Mounting heights: 10'-15'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-30-60


  • Gas: Natural or propane
  • BTU/h input: 60,000
  • Length: 31'-5"
  • Weight: 160
  • *Mounting heights: 11'-18'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-30-75


  • Gas: Natural or propane
  • BTU/h input: 75,000
  • Length: 31'-5"
  • Weight: 160
  • *Mounting heights: 12'-20'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-30-100


  • Gas: Natural or propane
  • BTU/h input: 75,000
  • Length: 31'-5"
  • Weight: 160
  • *Mounting heights: 13'-23'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-30-125


  • Gas: Natural or propane
  • BTU/h input: 100,000
  • Length: 31'-5"
  • Weight: 160
  • *Mounting heights: 14'-25'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-50


  • Gas: Natural or propane
  • BTU/h input: 50,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 11'-18'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-75


  • Gas: Natural or propane
  • BTU/h input: 75,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 12'-20'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-100


  • Gas: Natural or propane
  • BTU/h input: 100,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 13'-23'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-125


  • Gas: Natural or propane
  • BTU/h input: 125,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 14'-25'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-150


  • Gas: Natural or propane
  • BTU/h input: 150,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 15'-27'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-40-175


  • Gas: Natural or propane
  • BTU/h input: 175,000
  • Length: 41'-1"
  • Weight: 190
  • *Mounting heights: 16'-30'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-50-100


  • Gas: Natural or propane
  • BTU/h input: 100,000
  • Length: 50'-9"
  • Weight: 235
  • *Mounting heights: 15'-27'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-50-125


  • Gas: Natural or propane
  • BTU/h input: 125,000
  • Length: 50'-9"
  • Weight: 235
  • *Mounting heights: 15'-27'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-50-150


  • Gas: Natural or propane
  • BTU/h input: 150,000
  • Length: 50'-9"
  • Weight: 235
  • *Mounting heights: 16'-30'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-50-175


  • Gas: Natural or propane
  • BTU/h input: 175,000
  • Length: 50'-9"
  • Weight: 235
  • *Mounting heights: 17'-35'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-50-200


  • Gas: Natural or propane
  • BTU/h input: 200,000
  • Length: 50'-9"
  • Weight: 235
  • *Mounting heights: 18'-40'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-60-125


  • Gas: Natural or propane
  • BTU/h input: 125,000
  • Length: 60'-5"
  • Weight: 265
  • *Mounting heights: 16'-30'
  • Combustion chamber: aluminized steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-60-150


  • Gas: Natural or propane
  • BTU/h input: 150,000
  • Length: 60'-5"
  • Weight: 265
  • *Mounting heights: 17'-35'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-60-175


  • Gas: Natural or propane
  • BTU/h input: 175,000
  • Length: 60'-5"
  • Weight: 265
  • *Mounting heights: 17'-35'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-60-200


  • Gas: Natural or propane
  • BTU/h input: 200,000
  • Length: 60'-5"
  • Weight: 265
  • *Mounting heights: 18'-40'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-70-175


  • Gas: Natural or propane
  • BTU/h input: 175,000
  • Length: 70'-1"
  • Weight: 300
  • *Mounting heights: 18'-40'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-70-200


  • Gas: Natural or propane
  • BTU/h input: 200,000
  • Length: 70'-1"
  • Weight: 300
  • *Mounting heights: 19'-42'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

DX3L-80-200


  • Gas: Natural or propane
  • BTU/h input: 200,000
  • Length: 79'-9"
  • Weight: 330
  • *Mounting heights: 20'-45'
  • Combustion chamber: titanium coated steel
  • Radiant emitter tubes: 16 ga. 4" aluminized steel

* Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles. Not for residential use.  

Clearance to combustibles 

DX3L (20, 30, 40) - 50, 60



Mount
angle
Sides Top
Below

9" 6"47"
45°
Front 39"
Back 8"
10"47"

1 side
shield
Front 29"
Back 8"
6"47"

2 side
shields
9"6"47"

20 ft
from
burner
7"6"30"


DX3L (20, 30, 40)-75



Mount
angle
Sides Top
Below

9" 6"60"
45°
Front 39"
Back 8"
10"60"

1 side
shield
Front 29"
Back 8"
6"60"

2 side
shields
9"6"60"

20 ft
from
burner
7"6"30"


DX3L (30, 40, 50)-100



Mount
angle
Sides Top
Below

14" 6"66"
45°
Front 39"
Back 8"
10"66"

1 side
shield
Front 29"
Back 8"
6"66"

2 side
shields
9"6"66"

20 ft
from
burner
7"6"30"


DX3L (30, 40, 50, 60)-125



Mount
angle
Sides Top
Below

20" 6"76"
45°
Front 58"
Back 8"
10"76"

1 side
shield
Front 42"
Back 8"
6"76"

2 side
shields
20"6"76"

20 ft
from
burner
7"6"30"


DX3L (40, 50, 60)-150



Mount
angle
Sides Top
Below

24" 6"81"
45°
Front 58"
Back 8"
10"81"

1 side
shield
Front 42"
Back 8"
6"81"

2 side
shields
23"6"81"

20 ft
from
burner
11"6"44"


DX3L (40, 50, 60, 70)-175



Mount
angle
Sides Top
Below

34" 6"92"
45°
Front 63"
Back 8"
10"92"

1 side
shield
Front 54"
Back 8"
6"92"

2 side
shields
30"6"92"

20 ft
from
burner
11"6"44"


DX3L (50, 60, 70, 80)-200



Mount
angle
Sides Top
Below

41" 6"94"
45°
Front 63"
Back 8"
10"94"

1 side
shield
Front 54"
Back 8"
6"94"

2 side
shields
30"6"94"

20 ft
from
burner
11"6"44"


Clearances published in DX3L Series manual and on warning label supersede data shown on this brochure. Reference DX3L Series installation manual for complete information.

Heaters mounted on an angle between 0º and 45º must maintain clearances posted for 0º or 45º, whichever is greater.