DX2-SS-20-75
- Gas: Natural or propane
- BTU/h: 75,000
- Length: 21'-8"
- Weight: 145 lbs
- *Mounting heights: 11'-18'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-20-80
- Gas: Natural or propane
- BTU/h: 80,000
- Length: 21'-8"
- Weight: 145 lbs
- *Mounting heights: 11'-18'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-30-75
- Gas: Natural or propane
- BTU/h: 75,000
- Length: 31'-4"
- Weight: 195 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-30-80
- Gas: Natural or propane
- BTU/h: 80,000
- Length: 31'-4"
- Weight: 195 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-30-100
- Gas: Natural or propane
- BTU/h: 100,000
- Length: 31'-4"
- Weight: 195 lbs
- *Mounting heights: 13'-23'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-40-75
- Gas: Natural or propane
- BTU/h: 75,000
- Length: 41'-0"
- Weight: 235 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-40-80
- Gas: Natural or propane
- BTU/h: 80,000
- Length: 41'-0"
- Weight: 235 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-40-100
- Gas: Natural or propane
- BTU/h: 100,000
- Length: 41'-0"
- Weight: 235 lbs
- *Mounting heights: 13'-23'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-40-125
- Gas: Natural or propane
- BTU/h: 125,000
- Length: 41'-0"
- Weight: 235 lbs
- *Mounting heights: 14'-25'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-40-150
- Gas: Natural or propane
- BTU/h: 150,000
- Length: 41'-0"
- Weight: 235 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-50-100
- Gas: Natural or propane
- BTU/h: 100,000
- Length: 50'-8"
- Weight: 290 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-50-125
- Gas: Natural or propane
- BTU/h: 125,000
- Length: 50'-8"
- Weight: 290 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-50-150
- Gas: Natural or propane
- BTU/h: 150,000
- Length: 50'-8"
- Weight: 290 lbs
- *Mounting heights: 16'-30'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-50-175
- Gas: Natural or propane
- BTU/h: 175,000
- Length: 50'-8"
- Weight: 290 lbs
- *Mounting heights: 17'-35'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-60-125
- Gas: Natural or propane
- BTU/h: 125,000
- Length: 60'-4"
- Weight: 330 lbs
- *Mounting heights: 16'-30'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-60-150
- Gas: Natural or propane
- BTU/h: 150,000
- Length: 60'-4"
- Weight: 330 lbs
- *Mounting heights: 17'-35'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-60-175
- Gas: Natural or propane
- BTU/h: 175,000
- Length: 60'-4"
- Weight: 330 lbs
- *Mounting heights: 17'-35'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel

DX2-SS-60-200
- Gas: Natural or propane
- BTU/h: 200,000
- Length: 60'-4"
- Weight: 330 lbs
- *Mounting heights: 18'-40'
- Combustion chamber: stainless steel
- Radiant emitter tubes: 16 ga. 4” stainless steel
* Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles. Not for residential use.
Clearance to combustibles

DX2 (20, 30, 40)-75
Mount
angle |
Sides | Top | Below |
0° | 9" | 6" | 60" |
0° | Front 39" Back 8" | 10" | 60" |
0° | Front 29"
Back 8" | 6" | 60" |
0° | 9" | 6" | 60" |
0° |
7" | 6" | 30" |

DX2 (20, 30, 40)-80, 100
Mount
angle |
Sides | Top | Below |
0° | 14" | 6" | 66" |
0° | Front 39" Back 8" | 10" | 66" |
0° | Front 29"
Back 8" | 6" | 66" |
0° | 16" | 6" | 66" |
0° |
7" | 6" | 30" |

DX2 (40, 50)-125
Mount
angle |
Sides | Top | Below |
0° | 20" | 6" | 76" |
0° | Front 58" Back 8" | 10" | 76" |
0° | Front 42"
Back 8" | 6" | 76" |
0° | 20" | 6" | 76" |
0° |
7" | 6" | 30" |

DX2 (40, 50, 60)-150
Mount
angle |
Sides | Top | Below |
0° | 24" | 6" | 81" |
0° | Front 58" Back 8" | 10" | 81" |
0° | Front 42"
Back 8" | 6" | 81" |
0° | 23" | 6" | 81" |
0° |
11" | 6" | 44" |

DX2 (50, 60)-175
Mount
angle |
Sides | Top | Below |
0° | 34" | 6" | 92" |
0° | Front 63" Back 8" | 10" | 92" |
0° | Front 50"
Back 8" | 6" | 92" |
0° | 30" | 6" | 92" |
0° |
11" | 6" | 44" |

DX2 (60)-200
Mount
angle |
Sides | Top | Below |
0° | 41" | 6" | 94" |
0° | Front 63" Back 8" | 10" | 94" |
0° | Front 54"
Back 8" | 6" | 94" |
0° | 30" | 6" | 94" |
0° |
11" | 6" | 44" |
Clearances published in DX2-SS Series manual and on warning label supersede data shown on this page. Reference DX2-SS Series installation manual for complete information.
Heaters mounted on an angle between 0º and 45º must maintain clearances posted for 0º or 45º, whichever is greater.