DST-60N
- Gas: Natural
- BTU/h high fire: 60,000
- BTU/h low fire: 40,000
- Housing: stainless steel
- Length: 119”
- Weight: 150 lbs
- *Mounting heights: 8'-13'
- Approx. area heated: 20'x12'
DST-60P
- Gas: Propane
- BTU/h high fire: 60,000
- BTU/h low fire: 50,000
- Housing: stainless steel
- Length: 119”
- Weight: 150 lbs
- *Mounting heights: 8'-13'
- Approx. area heated: 20'x12'
DST-80N
- Gas: Natural
- BTU/h high fire: 80,000
- BTU/h low fire: 50,000
- Housing: stainless steel
- Length: 119”
- Weight: 150 lbs
- *Mounting heights: 9'-14'
- Approx. area heated: 20'x12'
* Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles. Not for indoor residential use.
Clearance to combustibles
DST-60
Mount
angle |
Sides | Top | Ends, *Below |
0° | 19" | 12" | Ends 16" Below 66" |
30° | Front 45"
Back 24" | 14" | Ends 16"
Below 45" |
DST-80
Mount
angle |
Sides | Top | Ends, *Below |
0° | 26" | 15" | Ends 16" Below 77" |
30° | Front 74"
Back 31" | 16" | Ends 16"
Below 74" |
Clearances published in DST Series manual and on warning label supersede data shown on this page. Reference DST Series installation manual for complete information.
Heaters mounted on an angle between 0° to 30° must maintain clearances posted for 0° or 30°; whichever is greater.
*The minimum mounting height is 79” above floor level.