DR-30

  • Gas: Natural or propane
  • BTU/h: 30,000 
  • Ceramic operating temp.: 1,780
  • Dimensions: 22.5”H x 12.75”W x 15.25”D
  • Ship weight: 18 lbs
  • *Mounting heights: 12'-14'

DR-30(S)

  • Gas: Natural or propane
  • BTU/h: 30,000 
  • Ceramic operating temp.: 1,780
  • Dimensions: 12.75”H x 22.5”W x 15.25”D
  • Ship weight: 18 lbs
  • *Mounting heights: 12'-14'

DR-45

  • Gas: Natural or propane
  • BTU/h: 45,000 
  • Ceramic operating temp.: 1,660
  • Dimensions: 22.5”H x 19.12”W x 15.25”D
  • Ship weight: 27 lbs
  • *Mounting heights: 12'-14'

DR-50

  • Gas: Natural or propane
  • BTU/h: 50,000 
  • Ceramic operating temp.: 1,690
  • Dimensions: 22.5”H x 19.12”W x 15.25”D
  • Ship weight: 27 lbs
  • *Mounting heights: 12'-14'

DR-55

  • Gas: Natural or propane
  • BTU/h: 55,000 
  • Ceramic operating temp.: 1,740
  • Dimensions: 22.5”H x 19.12”W x 15.25”D
  • Ship weight: 27 lbs
  • *Mounting heights: 13'-15'

DR-60

  • Gas: Natural or propane
  • BTU/h: 60,000 
  • Ceramic operating temp.: 1,780
  • Dimensions: 22.5”H x 19.12”W x 15.25”D
  • Ship weight: 27 lbs
  • *Mounting heights: 14'-16'

DR-75

  • Gas: Natural or propane
  • BTU/h: 75,000 
  • Ceramic operating temp.: 1,690
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 15'-17'

DR-80

  • Gas: Natural or propane
  • BTU/h: 80,000 
  • Ceramic operating temp.: 1,720
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 15'-17'

DR-85

  • Gas: Natural or propane
  • BTU/h: 85,000 
  • Ceramic operating temp.: 1,750
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 16'-18'

DR-90

  • Gas: Natural or propane
  • BTU/h: 90,000 
  • Ceramic operating temp.: 1,780
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 16'-18'

DR-95

  • Gas: Natural or propane
  • BTU/h: 95,000 
  • Ceramic operating temp.: 1,800
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 17'-20'

DR-95

  • Gas: Natural or propane
  • BTU/h: 95,000 
  • Ceramic operating temp.: 1,800
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 17'-20'

DR-100

  • Gas: Natural or propane
  • BTU/h: 100,000 
  • Ceramic operating temp.: 1,800
  • Dimensions: 22.5”H x 26.62”W x 15.25”D
  • Ship weight: 36 lbs
  • *Mounting heights: 17'-20'

DR-130

  • Gas: Natural or propane
  • BTU/h: 130,000 
  • Ceramic operating temp.: 1,810
  • Dimensions: 22.5”H x 32”W x 15.25”D
  • Ship weight: 45 lbs
  • *Mounting heights: 21'-24'

DR-160

  • Gas: Natural or propane
  • BTU/h: 160,000 
  • Ceramic operating temp.: 1,810
  • Dimensions: 22.5”H x 38.5”W x 15.25”D
  • Ship weight: 54 lbs
  • *Mounting heights: 24'-28'

*Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. 

Clearance to combustibles

Model Sides Back,
Top
Front/
Below
DR-30 30" Back 18"
Top 28"
72"
DR-30(S)
30"Back 18"
Top 28"
72"
DR-45
30"Back 18"
Top 28"
72"
DR-50
30"Back 18"
Top 34"
72"
DR-55
32"Back 18"
Top 40"
72"*
DR-60
32"Back 18"
Top 40"
72"*
DR-75
48"Back 30"
Top 42"
98"
DR-80
48"Back 30"
Top 42"
98"
DR-85
48"Back 30"
Top 42"
98"
DR-90
48"Back 30"
Top 42"
98"
DR-95
48"Back 30"
Top 52"
120"
DR-100
48"Back 30"
Top 52"
120"
DR-130
48"Back 18"
Top 52"
120"
DR-160
50"Back 32"
Top 62"
132"

*Clearance is 80 in. when heater is fitted with a parabolic reflector.

Clearances published in DR Series manual and on warning label supersede data shown on this page. Reference DR Series installation manual for complete information.  Always maintain the published clearances to combustibles. Not for residential use.