DR-30
- Gas: Natural or propane
- BTU/h: 30,000
- Ceramic operating temp.: 1,780
- Dimensions: 22.5”H x 12.75”W x 15.25”D
- Ship weight: 18 lbs
- *Mounting heights: 12'-14'
DR-30(S)
- Gas: Natural or propane
- BTU/h: 30,000
- Ceramic operating temp.: 1,780
- Dimensions: 12.75”H x 22.5”W x 15.25”D
- Ship weight: 18 lbs
- *Mounting heights: 12'-14'
DR-45
- Gas: Natural or propane
- BTU/h: 45,000
- Ceramic operating temp.: 1,660
- Dimensions: 22.5”H x 19.12”W x 15.25”D
- Ship weight: 27 lbs
- *Mounting heights: 12'-14'
DR-50
- Gas: Natural or propane
- BTU/h: 50,000
- Ceramic operating temp.: 1,690
- Dimensions: 22.5”H x 19.12”W x 15.25”D
- Ship weight: 27 lbs
- *Mounting heights: 12'-14'
DR-55
- Gas: Natural or propane
- BTU/h: 55,000
- Ceramic operating temp.: 1,740
- Dimensions: 22.5”H x 19.12”W x 15.25”D
- Ship weight: 27 lbs
- *Mounting heights: 13'-15'
DR-60
- Gas: Natural or propane
- BTU/h: 60,000
- Ceramic operating temp.: 1,780
- Dimensions: 22.5”H x 19.12”W x 15.25”D
- Ship weight: 27 lbs
- *Mounting heights: 14'-16'
DR-75
- Gas: Natural or propane
- BTU/h: 75,000
- Ceramic operating temp.: 1,690
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 15'-17'
DR-80
- Gas: Natural or propane
- BTU/h: 80,000
- Ceramic operating temp.: 1,720
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 15'-17'
DR-85
- Gas: Natural or propane
- BTU/h: 85,000
- Ceramic operating temp.: 1,750
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 16'-18'
DR-90
- Gas: Natural or propane
- BTU/h: 90,000
- Ceramic operating temp.: 1,780
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 16'-18'
DR-95
- Gas: Natural or propane
- BTU/h: 95,000
- Ceramic operating temp.: 1,800
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 17'-20'
DR-95
- Gas: Natural or propane
- BTU/h: 95,000
- Ceramic operating temp.: 1,800
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 17'-20'
DR-100
- Gas: Natural or propane
- BTU/h: 100,000
- Ceramic operating temp.: 1,800
- Dimensions: 22.5”H x 26.62”W x 15.25”D
- Ship weight: 36 lbs
- *Mounting heights: 17'-20'
DR-130
- Gas: Natural or propane
- BTU/h: 130,000
- Ceramic operating temp.: 1,810
- Dimensions: 22.5”H x 32”W x 15.25”D
- Ship weight: 45 lbs
- *Mounting heights: 21'-24'
DR-160
- Gas: Natural or propane
- BTU/h: 160,000
- Ceramic operating temp.: 1,810
- Dimensions: 22.5”H x 38.5”W x 15.25”D
- Ship weight: 54 lbs
- *Mounting heights: 24'-28'
*Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data.
Clearance to combustibles
Model | Sides | Back, Top | Front/ Below |
DR-30 | 30" | Back 18" Top 28" | 72" |
DR-30(S) | 30" | Back
18"
Top 28" | 72" |
DR-45 | 30" | Back
18"
Top 28" | 72" |
DR-50 | 30" | Back
18"
Top 34" | 72" |
DR-55 | 32" | Back
18"
Top 40" | 72"* |
DR-60 | 32" | Back
18"
Top 40" | 72"* |
DR-75 | 48" | Back
30"
Top 42" | 98" |
DR-80 | 48" | Back
30"
Top 42" | 98" |
DR-85 | 48" | Back
30"
Top 42" | 98" |
DR-90 | 48" | Back
30"
Top 42" | 98" |
DR-95 | 48" | Back
30"
Top 52" | 120" |
DR-100 | 48" | Back
30"
Top 52" | 120" |
DR-130 | 48" | Back
18"
Top 52" | 120" |
DR-160 | 50" | Back
32"
Top 62" | 132" |
*Clearance is 80 in. when heater is fitted with a parabolic reflector.
Clearances published in DR Series manual and on warning label supersede data shown on this page. Reference DR Series installation manual for complete information. Always maintain the published clearances to combustibles. Not for residential use.