DET3-20-65
- Gas: natural or propane
- BTU/h
high fire: 65,000
- BTU/h low fire: 50,000
- Length: 21'-9"
- Weight: 120 lbs
- *Mounting heights: 9'-14'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-20-75
- Gas: natural or propane
- BTU/h
high fire: 55,000
- BTU/h low fire: 50,000
- Length: 21'-9"
- Weight: 120 lbs
- *Mounting heights: 10'-15'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-30-65
- Gas: natural or propane
- BTU/h
high fire: 65,000
- BTU/h low fire: 50,000
- Length: 31'-5"
- Weight: 160 lbs
- *Mounting heights: 10'-15'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-30-75
- Gas: natural or propane
- BTU/h
high fire: 75,000
- BTU/h low fire: 50,000
- Length: 31'-5"
- Weight: 160 lbs
- *Mounting heights: 11'-18'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-30-100
- Gas: natural or propane
- BTU/h
high fire: 75,000
- BTU/h low fire: 65,000
- Length: 31'-5"
- Weight: 160 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-30-125
- Gas: natural or propane
- BTU/h
high fire: 125,000
- BTU/h low fire: 82,000
- Length: 31'-5"
- Weight: 160 lbs
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-65
- Gas: natural or propane
- BTU/h
high fire: 65,000
- BTU/h low fire: 50,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 11'-18'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-75
- Gas: natural or propane
- BTU/h
high fire: 75,000
- BTU/h low fire: 50,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 11'-18'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-100
- Gas: natural or propane
- BTU/h
high fire: 100,000
- BTU/h low fire: 65,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-125
- Gas: natural or propane
- BTU/h
high fire: 125,000
- BTU/h low fire: 82,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-150
- Gas: natural or propane
- BTU/h
high fire: 150,000
- BTU/h low fire: 100,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 14'-25'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-40-175
- Gas: natural or propane
- BTU/h
high fire: 175,000
- BTU/h low fire: 125,000
- Length: 41'-1"
- Weight: 190 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-50-125
- Gas: natural or propane
- BTU/h
high fire: 125,000
- BTU/h low fire: 82,000
- Length: 50'-9"
- Weight: 235 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: aluminized steel or titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-50-150
- Gas: natural or propane
- BTU/h
high fire: 150,000
- BTU/h low fire: 100,000
- Length: 50'-9"
- Weight: 235 lbs
- *Mounting heights: 15'-27'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-50-175
- Gas: natural or propane
- BTU/h
high fire: 175,000
- BTU/h low fire: 125,000
- Length: 50'-9"
- Weight: 235 lbs
- *Mounting heights: 16'-30'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-50-200
- Gas: natural or propane
- BTU/h
high fire: 200,000
- BTU/h low fire: 145,000
- Length: 50'-9"
- Weight: 235 lbs
- *Mounting heights: 17'-35'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-60-150
- Gas: natural or propane
- BTU/h
high fire: 150,000
- BTU/h low fire: 100,000
- Length: 60'-5"
- Weight: 265 lbs
- *Mounting heights: 16'-30'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-60-175
- Gas: natural or propane
- BTU/h
high fire: 175,000
- BTU/h low fire: 125,000
- Length: 60'-5"
- Weight: 265 lbs
- *Mounting heights: 16'-30'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
DET3-60-200
- Gas: natural or propane
- BTU/h
high fire: 200,000
- BTU/h low fire: 145,000
- Length: 60'-5"
- Weight: 265 lbs
- *Mounting heights: 17'-35'
- Combustion chamber: titanium treated steel
- Radiant emitter tubes: 16 ga. 4” O.D. hot-rolled steel
* Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles. Not for residential use.
Clearance to combustibles
DET3 (20, 30, 40) - 65, 75
Mount
angle |
Sides | Top | Below |
0° |
9" | 6" | 60" |
45° | Top 39" Below 8" | 10" | 60" |
0° 1 side shield | Top 29"
Below 8" | 6" | 60" |
0° 2 side shields | 9" | 6" | 60" |
0° 20 ft from burner | 7" | 6" | 30" |
DET3 (30, 40) - 100
Mount
angle |
Sides | Top | Below |
0° |
14" | 6" | 66" |
45° | Top 39" Below 8" | 10" | 66" |
0° 1 side shield | Top 29"
Below 8" | 6" | 66" |
0° 2 side shields | 16" | 6" | 66" |
0° 20 ft from burner | 7" | 6" | 30" |
DET3 (30, 40, 50) - 125
Mount
angle |
Sides | Top | Below |
0° |
20" | 6" | 76" |
45° | Top 58" Below 8" | 10" | 76" |
0° 1 side shield | Top 42"
Below 8" | 6" | 76" |
0° 2 side shields | 20" | 6" | 76" |
0° 20 ft from burner | 7" | 6" | 30" |
DET3 (40, 50, 60) - 150
Mount
angle |
Sides | Top | Below |
0° |
24" | 6" | 81" |
45° | Top 58" Below 8" | 10" | 81" |
0° 1 side shield | Top 42"
Below 8" | 6" | 81" |
0° 2 side shields | 23" | 6" | 81" |
0° 20 ft from burner | 11" | 6" | 44" |
DET3 (40, 50, 60, 70) - 175
Mount
angle |
Sides | Top | Below |
0° |
34" | 6" | 92" |
45° | Top 63" Below 8" | 10" | 92" |
0° 1 side shield | Top 50"
Below 8" | 6" | 92" |
0° 2 side shields | 30" | 6" | 92" |
0° 20 ft from burner | 11" | 6" | 44" |
DET3 (40, 50, 60, 70) - 200
Mount
angle |
Sides | Top | Below |
0° |
41" | 6" | 94" |
45° | Top 63" Below 8" | 10" | 94" |
0° 1 side shield | Top 54"
Below 8" | 6" | 94" |
0° 2 side shields | 30" | 6" | 94" |
0° 20 ft from burner | 11" | 6" | 44" |
Clearances published in DET3 Series manual and on warning label supersede data shown on this webpage. Reference DET3 Series installation manual for complete information.
Heaters mounted on an angle between 0º and 45º must maintain clearances posted for 0º or 45º, whichever is greater.