CX3-30-50
- Gas: Natural or propane
- BTU/h input: 50,000
- Length: 31'-5"
- Weight: 185
- *Mounting heights: 10'-15'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-30-60
- Gas: Natural or propane
- BTU/h input: 60,000
- Length: 31'-5"
- Weight: 185
- *Mounting heights: 11'-18'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-30-75
- Gas: Natural or propane
- BTU/h input: 75,000
- Length: 31'-5"
- Weight: 185
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-30-80
- Gas: Natural or propane
- BTU/h input: 80,000
- Length: 31'-5"
- Weight: 185
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-30-85
- Gas: Natural or propane
- BTU/h input: 85,000
- Length: 31'-5"
- Weight: 185
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-40-50
- Gas: Natural or propane
- BTU/h input: 50,000
- Length: 41'-1"
- Weight: 215
- *Mounting heights: 10'-15'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-40-75
- Gas: Natural or propane
- BTU/h input: 75,000
- Length: 41'-1"
- Weight: 215
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-40-80
- Gas: Natural or propane
- BTU/h input: 80,000
- Length: 41'-1"
- Weight: 215
- *Mounting heights: 12'-20'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-40-85
- Gas: Natural or propane
- BTU/h input: 85,000
- Length: 41'-1"
- Weight: 215
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-50-80
- Gas: Natural or propane
- BTU/h input: 80,000
- Length: 41'-1"
- Weight: 260
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
CX3-50-85
- Gas: Natural or propane
- BTU/h input: 85,000
- Length: 41'-1"
- Weight: 260
- *Mounting heights: 13'-23'
- Combustion chamber: aluminized steel
- Radiant emitter tubes: 16 ga. 4" aluminized steel
* Mounting heights are provided as a guideline. Actual conditions may dictate variations from the above data. Always maintain the published clearances to combustibles. Not for residential use.
Clearance to combustibles
CX3 Model |
Mount
angle |
Front
side |
Back
side |
Top | Below |
(30, 40) - 50, 60, 75 |
0° | 16" | 16" | 6" | 43" |
45° | 36" | 9" | 10" | 33" | |
1 side
shield |
0° | 33" | 9" | 6" | 43" |
2 side
shields |
0° | 9" | 9" | 6" | 46" |
20 ft from burner |
0° | 9" | 9" | 6" | 32" |
|
|||||
(30, 40, 50) -
80, 85 |
0° | 16" | 16" | 6" | 43" |
45° | 36" | 8" | 10" | 33" | |
1 side
shield |
0° | 29" | 8" | 6" | 43" |
2 side
shields |
0° | 9" | 9" | 6" | 46" |
20 ft from burner |
0° | 7" | 7" | 6" | 32" |
Clearances published in CX3 Series manual and on warning label supersede data shown on this page. Reference CX3 Series installation manual for complete information.